HD-AN300 Intelligent Anaerobic and Microaerophilic Incubation System
Product

Intelligent Anaerobic and Microaerophilic Culture System

HD-AN300 Export Ready

A laboratory product in the Anaerobic Incubation System range for microbiology testing, sample preparation, pathogen detection or laboratory workflow support.

Request a Quote

Product Introduction

The Intelligent Anaerobic and Microaerophilic Culture System is a multifunctional microbial culture environment generation system designed for anaerobic bacteria, microaerophilic bacteria, special oxygen concentration culture, and cell culture applications.

The system uses a vacuum replacement and exhaust principle to precisely control gas pressure changes inside the culture jar, thereby creating controlled anaerobic, microaerophilic, carbon dioxide, or customized oxygen concentration environments.

It is suitable for food safety testing, microbiology laboratories, pharmaceutical and biopharmaceutical quality control, environmental testing, agricultural and animal husbandry testing, research institutions, and comprehensive laboratory applications.

Working Principle

The system creates the required culture environment through vacuum replacement and gas exchange.

During operation, the instrument first performs self-detection and measures the local atmospheric pressure to obtain an accurate initial value. Then, by controlling vacuum extraction, gas replacement, and gas pressure variation, the system adjusts the oxygen concentration and gas composition inside the culture jar.

This process allows the system to generate anaerobic environments with 0% oxygen, microaerophilic environments with 6% oxygen, and other customized oxygen concentration conditions according to different microbial culture requirements.

The system can also automatically check gas source pressure, pipeline connection, jar sealing, lid sealing, and catalyst activity to help ensure stable culture conditions.

Main Applications

The Intelligent Anaerobic and Microaerophilic Culture System is suitable for the isolation, culture, and detection of microorganisms requiring anaerobic, microaerophilic, or special oxygen concentration environments.

Typical applications include:

  • Anaerobic bacterial culture
  • Microaerophilic bacterial culture
  • Cell culture under controlled gas conditions
  • Food safety microbiological testing
  • Pharmaceutical and biopharmaceutical microbiology testing
  • Environmental microbiology testing
  • Agricultural and animal husbandry microbiology testing
  • Drinking natural mineral water microbiological testing
  • Research and teaching laboratories

The system can be used for the detection and culture of microorganisms such as Campylobacter jejuni, hemolytic streptococcus, Bifidobacterium, lactic acid bacteria, Shigella, and Clostridium perfringens.

Technical Specifications

ItemSpecification
Product NameIntelligent Anaerobic and Microaerophilic Culture System
ModelHD-AN300
System PrincipleVacuum replacement and exhaust control
Main FunctionGeneration of anaerobic, microaerophilic, CO₂, and special oxygen concentration environments
Anaerobic EnvironmentOxygen concentration 0%
Microaerophilic EnvironmentOxygen concentration 6%
Operation ModeLarge color touch screen
Control FunctionOne-click generation of anaerobic, microaerophilic, Campylobacter, and CO₂ culture conditions
Multi-Jar ModeMulti-channel design for controlling multiple culture jars
Waste Gas TreatmentBuilt-in waste gas treatment device
Quality Control CheckGas source pressure, pipeline connection, jar sealing, lid sealing, and catalyst activity
Gas Consumption for Microaerophilic Culture≤2 L / 12 plates
Gas Consumption for Anaerobic Culture≤7 L / 12 plates
CatalystReusable anaerobic catalyst
Catalyst Activity DetectionOptional on/off control, 5-level activity evaluation
Culture Jar Options7 or more culture jar specifications
Printing FunctionBuilt-in printing module
Oxygen MonitoringWireless oxygen concentration monitoring device
Monitoring ParametersOxygen concentration, temperature, humidity
Data FunctionData storage and export
ConfigurationMain unit, culture jars, pressure reducing valve, catalyst, printer, wireless oxygen monitor, anaerobic mixed gas
Price RangeRMB 200,000–500,000, depending on configuration
Origin CategoryChina-made
Application FieldsEnvironmental testing, biological industry, agriculture, forestry, animal husbandry, fishery, pharmaceutical and biopharmaceutical, comprehensive laboratories

System Functions

Anaerobic Environment Generation

The system can create a 0% oxygen anaerobic environment, making it suitable for the culture of strict anaerobic bacteria and microorganisms that require oxygen-free conditions.

Microaerophilic Environment Generation

The system can generate a 6% oxygen microaerophilic environment, suitable for microorganisms such as Campylobacter and other bacteria that require low oxygen levels for growth.

Special Oxygen Concentration Control

In addition to standard anaerobic and microaerophilic modes, the system can generate special oxygen concentration environments according to different microbial culture needs.

One-Click Operation

The system supports one-click generation of anaerobic, microaerophilic, Campylobacter, and carbon dioxide culture conditions. Operators do not need to manually set complex parameters, which improves ease of use and reduces operation errors.

Multi-Jar Control

The system is equipped with multiple channels and can control multiple culture jars at the same time. This design helps avoid waiting time and manual jar replacement during the environment generation process.

Waste Gas Treatment

A built-in waste gas treatment device automatically processes discharged harmful gases, reducing the risk of laboratory contamination and improving operating safety.

Core Components

The system is mainly composed of the system main unit, culture jars, pressure reducing valve, anaerobic catalyst, printer, wireless oxygen concentration monitoring device, and anaerobic mixed gas.

System Main Unit

The main unit controls vacuum extraction, gas replacement, pressure regulation, program operation, environment generation, data display, and system self-checking.

Culture Jars

The system is equipped with transparent culture jars. The clear jar body allows users to observe the culture status conveniently. Different jar sizes can be selected for different culture applications.

Pressure Reducing Valve

The pressure reducing valve is used to adjust gas source pressure. During adjustment, the instrument can display gas source pressure in real time, reducing the need to observe the pointer on the valve manually.

Anaerobic Catalyst

The system includes a reusable anaerobic catalyst to help achieve 0% oxygen concentration. The catalyst can be reused and does not generate chemical waste, making it suitable for routine laboratory use.

Built-in Printer

The built-in printing module allows users to print selected operation information, test records, or culture environment generation data according to laboratory documentation requirements.

Wireless Oxygen Monitoring Device

The wireless oxygen concentration monitoring device can monitor oxygen concentration during the culture process in real time. It can also monitor temperature and humidity. Data can be stored and exported for quality control and result analysis.

Culture Jar Options

The system supports seven or more culture jar specifications to meet different laboratory workloads and sample types.

Available jar options include:

Culture Jar TypeCapacity / Application
Small Culture JarHolds 6 pieces of 90 mm culture dishes
Medium Culture JarHolds 12 pieces of 90 mm culture dishes
Double Culture JarHolds 24 pieces of 90 mm culture dishes
Campylobacter-Specific Culture JarHolds 8 double-well Campylobacter culture plates and 8 enrichment tubes
Microbial Identification Culture JarHolds 4 ELISA plates, cell culture plates, or identification strip culture plates
Shigella-Specific Culture JarHolds 10 culture bags
Large Culture JarHolds 36 pieces of 90 mm culture dishes, or four 250 ml Erlenmeyer flasks, or 8 homogenized sample bags

The system can be expanded according to workload by adding culture jars of different sizes.

Quality Control Program

Each time the system generates a required gas environment, it performs five key checks on the culture jar:

  1. Gas source pressure check
  2. Pipeline connection check
  3. Jar body sealing check
  4. Jar lid sealing check
  5. Catalyst activity check

These quality control procedures help ensure that the culture jar maintains proper sealing and stable internal gas conditions during microbial incubation.

Oxygen Concentration Monitoring

The system can be configured with a wireless oxygen concentration monitoring device and built-in data processing software.

The monitoring device can:

  • Monitor oxygen concentration in real time
  • Monitor temperature
  • Monitor humidity
  • Store monitoring data
  • Export monitoring information
  • Support data analysis during the culture process

The sensor is compact and easy to place inside culture containers, making it convenient for routine laboratory monitoring.

Detection and Culture Workflow

A typical workflow includes:

  1. Prepare culture plates, enrichment tubes, culture bags, or other samples
  2. Place samples into the selected culture jar
  3. Connect the jar to the system channel
  4. Select anaerobic, microaerophilic, Campylobacter, CO₂, or custom culture mode
  5. Start one-click environment generation
  6. System performs pressure, sealing, pipeline, and catalyst checks
  7. The required gas environment is generated automatically
  8. Culture jar is transferred to the incubator for microbial culture
  9. Oxygen concentration, temperature, and humidity can be monitored if required
  10. Data can be printed, stored, or exported

Applicable Microorganisms

The system is suitable for the culture and detection of microorganisms that require anaerobic, microaerophilic, or special gas environments, including:

  • Campylobacter jejuni
  • Hemolytic streptococcus
  • Bifidobacterium
  • Lactic acid bacteria
  • Shigella
  • Clostridium perfringens
  • Other anaerobic bacteria
  • Other microaerophilic bacteria
  • Special oxygen concentration culture microorganisms

Applicable Laboratories and Institutions

The Intelligent Anaerobic and Microaerophilic Culture System is suitable for:

  • Food safety testing laboratories
  • Pharmaceutical microbiology laboratories
  • Biopharmaceutical quality control laboratories
  • Environmental testing laboratories
  • Agricultural and animal husbandry testing institutions
  • Disease control laboratories
  • Drinking water testing laboratories
  • Research institutes
  • Universities and teaching laboratories
  • Third-party testing laboratories

Product Advantages

Accurate Gas Environment Control

The system uses vacuum replacement and pressure control to accurately generate the required gas environment inside the culture jar.

Multiple Culture Modes

It supports anaerobic, microaerophilic, Campylobacter, carbon dioxide, and customized oxygen concentration culture conditions.

One-Click Operation

Standard culture environments can be generated with one click, reducing manual operation and improving testing efficiency.

Multi-Jar Processing

The multi-channel design allows simultaneous control of multiple culture jars, making it suitable for laboratories with different sample volumes.

Built-in Quality Control

The system automatically checks pressure, pipeline connection, jar sealing, lid sealing, and catalyst activity before culture, improving reliability.

Lower Gas Consumption

The system helps reduce gas consumption, with microaerophilic gas consumption ≤2 L / 12 plates and anaerobic gas consumption ≤7 L / 12 plates.

Reusable Catalyst

The anaerobic catalyst can be reused and does not produce chemical waste, supporting long-term laboratory use.

Real-Time Monitoring

Wireless oxygen concentration monitoring supports real-time tracking of oxygen, temperature, and humidity during culture.

Expandable Configuration

Culture jars and gas cylinder connections can be upgraded according to laboratory workload and future testing needs.

Installation Requirements

Before installation, the laboratory should prepare a stable workbench, appropriate power supply, gas source connection, and suitable space for the system main unit and culture jars.

The instrument should be placed in a clean, dry, and well-ventilated laboratory environment. Gas cylinders and pressure reducing valves should be installed according to laboratory safety requirements.

Professional installation and training are recommended to ensure proper gas connection, system calibration, operation setup, and user safety.

Maintenance Requirements

Routine maintenance includes checking gas source pressure, inspecting pipeline connections, cleaning culture jars, checking sealing rings, verifying catalyst activity, maintaining the printer, and backing up monitoring data.

The reusable anaerobic catalyst should be stored and used according to operating requirements. Culture jars and lids should be regularly checked to ensure reliable sealing performance.

Operators should also perform regular system self-checks and quality control checks to maintain stable culture performance.

Packaging and Export

The system can be packed with protective materials to ensure safe transportation of the main unit, culture jars, pressure reducing valve, catalyst, printer, wireless monitoring device, and related accessories.

For export projects, technical documents, operation instructions, configuration guidance, installation support, and after-sales service can be provided according to customer requirements.

Customization Service

The system can be configured according to different laboratory workloads and application scenarios.

Optional customization may include:

  • Additional culture jars
  • Different culture jar sizes
  • Additional gas cylinder connections
  • Software upgrade
  • Monitoring function expansion
  • Application-specific culture configurations
  • Data printing and export requirements

Final configuration can be adjusted according to the customer’s laboratory workflow, sample volume, and target microorganisms.

Related Equipment and Applications

This product can be used as part of a complete microbial culture and testing solution. Related equipment and application systems include:

  • Intelligent anaerobic microbial culture system
  • Multifunctional microbial culture system
  • Anaerobic incubator
  • Anaerobic glove box
  • Anaerobic workstation
  • Tri-gas incubator
  • Anaerobic chamber
  • Anaerobic culture system
  • Anaerobic culture device
  • Anaerobic gas generation bag
  • Microaerophilic culture system
  • Low-oxygen culture system
  • Multifunctional anaerobic environment generation system

FAQ

1. What is the main function of this system?

The system is used to generate anaerobic, microaerophilic, carbon dioxide, and special oxygen concentration environments for microbial culture.

2. What oxygen concentration can the system generate?

It can generate a 0% oxygen anaerobic environment, a 6% oxygen microaerophilic environment, and other customized oxygen concentration conditions.

3. Can the system culture Campylobacter?

Yes. The system supports one-click generation of Campylobacter culture conditions and can be used for Campylobacter jejuni testing according to food safety laboratory requirements.

4. Can multiple culture jars be used at the same time?

Yes. The system uses a multi-channel design and can control multiple culture jars simultaneously.

5. Does the system include oxygen monitoring?

Yes. It can be equipped with a wireless oxygen concentration monitoring device that can also monitor temperature and humidity.

6. Is the anaerobic catalyst reusable?

Yes. The anaerobic catalyst can be reused and does not produce chemical waste.

7. What culture jar sizes are available?

The system supports seven or more culture jar specifications, including small, medium, double, Campylobacter-specific, microbial identification, Shigella-specific, and large culture jars.

8. Can the system be upgraded later?

Yes. Different quantities and sizes of culture jars can be added according to workload, and gas cylinder connections and software can also be upgraded.

9. What industries is this product suitable for?

It is suitable for environmental testing, biological industry, agriculture, forestry, animal husbandry, fishery, pharmaceutical and biopharmaceutical laboratories, food safety testing, and research institutions.

10. Are product specifications fixed?

Product appearance, structure, performance, and specifications may change due to continuous product upgrades. Final configuration and parameters should be confirmed according to the latest manufacturer information.